力士樂(lè)放大器維修公司:F262 External Short at Status Outputs狀態(tài)輸出處的外部短路。另外,有些伺服電機(jī)控制器是針對(duì)伺服電機(jī)特殊使用而的,也可能專為某些產(chǎn)品而制造,選用哪種控制信形式因設(shè)計(jì)師個(gè)人規(guī)劃理念而定,或選用控制器與驅(qū)動(dòng)器一體規(guī)劃,絡(luò)式遠(yuǎn)程控制,這些不是通用伺服電機(jī)評(píng)論的規(guī)模,但工作理論及工作形式是相同的。
Description:說(shuō)明:Status outputs are monitored for short circuits and thermal overload.監(jiān)測(cè)狀態(tài)輸出是否存在短路和熱過(guò)載。
If output current exceeds 350mA for about 1μs, then this is acknowledged as a short circuit and the pertinent channel is shut off.The output remains off unti the error is cleared.
•如果輸出電流超過(guò)350mA約1μs,則為確認(rèn)為短路,并關(guān)閉相關(guān)通道。在清除錯(cuò)誤之前,輸出保持關(guān)閉。
Cause:原因:
1. Short circuited outputs (X2/6, X2/7, X2/8, X2/9, X2/10, X2/20,X2/21, X2/22)
短路輸出(X2/6、X2/7、X2/8、X2/9、X2/10、X2/20、X2/21,X2/22)
2. One or more outputs are overloaded.
一個(gè)或多個(gè)輸出過(guò)載。
Remedy:解決措施:
For 1. Eliminate short circuit or limit switching current (< 350 mA)
對(duì)于1。消除短路或限制開(kāi)關(guān)電流(<350 mA)
For 2. Drop current, depending on output, to < 80 mA.
對(duì)于2。根據(jù)輸出,將電流降至<80 mA。